UPS Battery Backup

$94.95

or 4 payments of $23.74 with Afterpay

SKU: 15 Category:

Description

The cutest and smallest ups in the world

 

Features

  • Fully digitized microprocessor controlled
  • Energy saving (UPS sleep mode)
  • 50/60Hz frequency auto sensing
  • Buzzer can be muted by pressing “on/off button”
  • Single PCB with reliable design
  • AC line ok (”Power” LED always on)
  • Cold start (DC power on)
  • Back up mode (”Power” LED slow flash)
  • Replace battery (”Power” LED fast flash)
  • Short circuit and overload protection
  • Advanced battery management (ABM technology)
  • Automatic diagnostics & battery check
  • Bypass output filter for critical load
  • EMI/RFI noise filter

 

Package Contents

  • iCute UPS

MHC UPS Brochure

Additional information

SPECIFICATIONS
UPS Capacity

385VA, 530VA, 730VA

Voltage (Single Phase)

240V, 170V ~ 280 at line input

Frequency

50Hz or 60 Hz +/- 10% (auto sensing)

No. of sockets

2 x IEC C13 (10A), 2 x IEC C13 (10A) Battery Backup
2 x IEC C13 (10A) Surge Protection

Voltage (on battery)

Simulated sine wave at 240V <+/- 5% AVR Controlled by PWM

Frequency (on battery)

50 or 60 Hz +/- 0.3 Hz

Transfer Time

< 10 milliseconds, including detection time

Unit Input

Circuit breaker for overload & short circuit protection

Overload Protection

UPS automatic shutdown if overload exceeds 105% of
nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds

Short Circuit

UPS output cut off immediately

Spike Protection

460 Joules, 2ms

Battery Type

Sealed, maintenance-free lead acid batteries with 3-5 years
typical life time

Typical Recharge Time (to 90% of full capacity)

6 hours

Back-up Time (A PC with 15" monitor)

4 – 6 minutes, 8 – 10 minutes

Back-up Time (A PC with 15" LCD)

8 – 12 minutes, 15 – 18 minutes

Protection

Automatic self – test, Over discharge protection, short circuit
protection by fuse

Net Weight Kg

1.6, 2.6

Dimensions W x D x H

95 x 95 x 158 mm, 95 x 138 x 158 mm

Dry contact (option) Interface

Sends battery low & power failure signals, and receives shutdown
signal from computer

USB (option) Interface

Detect battery low, Schedule UPS ON/OFF, AC input / output
power status display

Battery Back-up

Slow beeping sound every 4 seconds
(Buzzer can be muted by pressing main switch button)

Battery Low

Rapid beeping sound every seconds

100% load Overload

Continue beeping sound every 4 seconds
Continue beeping sound

Ambient operation environment

3,500 meters max, elevation. 0-95% humidity (No-condensing water) , 0-40 deg C

Audible noise environment

<40dBA (1 meter from surface)